• DocumentCode
    3624991
  • Title

    Diagnostic Tools for Evaluation of the Quality of the Anisotropic Conductive Adhesive Joints

  • Author

    Ales Duraj;Pavel Mach

  • Author_Institution
    Department of Electrotechnology, Faculty of Electrical Engineering, Czech Technical University, Prague 6, 166 27, Czech Republic. E-mail: duraja@centrum.cz
  • fYear
    2006
  • fDate
    5/1/2006 12:00:00 AM
  • Firstpage
    132
  • Lastpage
    136
  • Abstract
    Isotropic and anisotropic electrically conductive adhesives (ICAs and AC As) are materials for special applications in electronic assembly. Quality of these adhesive joints is evaluated according of their electrical and mechanical properties. This paper is focused on evaluation of quality of Anisotropic Conductive Adhesives. Especially dependence of electrical resistance, noise and nonlinearity on bonding pressure is the main purpose of this research. Effect of curing (bonding) pressure ofACA was also analyzed with scanning electron microscope (SEM). Also influence of three different types of surface finishes (Cu, Cu+Sn, Cu+Ni/Au) of printed circuit boards has been examined and then evaluated effects on measured parameters.
  • Keywords
    "Anisotropic magnetoresistance","Conductive adhesives","Bonding","Scanning electron microscopy","Independent component analysis","Conducting materials","Assembly","Mechanical factors","Electric resistance","Circuit noise"
  • Publisher
    ieee
  • Conference_Titel
    Electronics Technology, 2006. ISSE ´06. 29th International Spring Seminar on
  • ISSN
    2161-2528
  • Print_ISBN
    1-4244-0550-5
  • Electronic_ISBN
    2161-2064
  • Type

    conf

  • DOI
    10.1109/ISSE.2006.365373
  • Filename
    4216013