Capture cavity II results at FNAL
Author
J. Branlard;B. Chase;G. Cancelo;R. Carcagno;H. Edwards;R. Fliller;B. Hanna;E. Harms;A. Hocker;T. Koeth;M. Kucera;A. Makulski;U. Mavric;M. McGee;A. Paytyan;Y. Pischalnikov;P. Prieto;R. Rechenmacher;J. Reid;N. Wilcer;K. Treptow;T. Zmuda
Author_Institution
FNAL, Batavia, 60510 IL U.S.A.
fYear
2007
fDate
6/1/2007 12:00:00 AM
Firstpage
2245
Lastpage
2247
Abstract
As part of the research and development towards the International Linear Collider (ILC), several test facilities have been developed at Fermilab. This paper presents the latest Low Level RF (LLRF) results obtained with Capture Cavity II (CCII) at the ILC Test Accelerator (ILCTA) test facility. The main focus will be on controls and RF operations using the SIMCON based LLRF system developed in DESY. Details about hardware upgrades and future work will be discussed.
Keywords
"Radio frequency","Tuners","Resonance","Resonant frequency","Tuning","Test facilities","Testing","Hardware","Research and development","Life estimation"