• DocumentCode
    3628502
  • Title

    The modeling of temperature field in the sensor zone

  • Author

    Antanas Dumcius;Vygantas Augutis;Darius Gailius

  • Author_Institution
    Department of Electronics Engineering, Kaunas University of Technology, Lithuania
  • fYear
    2008
  • Firstpage
    691
  • Lastpage
    696
  • Abstract
    Temperature fields in the region of the temperature sensors are simulated. Two versions of the sensors placement relative to the heat transfer agent are analyzed. It is established that in the case of sinking the sensor with the bushing into the heat-transfer agent flow the sensor and the part of the surface of the wall of pipe must be covered with thermal insulation. In this case the temperature of the thermo-insulated sensor is equal to the temperature of heat-transfer agent (70° C). If sensor walls are covered with sediment layer of 0.5 mm thickness the temperature of the sensor body can be within the 65.38°C - 59.3° C range. When sensor is fastened to the surface of a pipe and is thermally isolated, the temperature of the body of sensor can achieve the 69.993° C - 69.934° C limits. The thermal isolation, the cable shell and cupper wire are the main factors, which influences the temperature inside the sensor.
  • Keywords
    "Temperature sensors","Temperature measurement","Thermal sensors","Semiconductor device measurement","Sediments","Fluid flow measurement","Fluid flow"
  • Publisher
    ieee
  • Conference_Titel
    Information Technology Interfaces, 2008. ITI 2008. 30th International Conference on
  • ISSN
    1330-1012
  • Print_ISBN
    978-953-7138-12-7
  • Type

    conf

  • DOI
    10.1109/ITI.2008.4588495
  • Filename
    4588495