DocumentCode :
3628579
Title :
An online phase margin monitor for digitally controlled switched-mode power supplies
Author :
Jeff Morroni;Regan Zane;Dragan Maksimovic
Author_Institution :
Colorado Power Electronics Center, University of Colorado at Boulder, USA
fYear :
2008
Firstpage :
859
Lastpage :
865
Abstract :
This paper presents a practical injection-based method for continuous monitoring of the crossover frequency and phase margin in digitally controlled switched-mode power supplies (SMPS). The proposed approach is based on Middlebrook’s loop-gain measurement technique [1], adapted to digital controller implementation. A digital square-wave signal is injected in the loop, and the injection signal frequency is adjusted while monitoring loop signals to obtain the system crossover frequency and phase margin online, i.e., during normal SMPS operation. The approach does not require open loop or steady-state SMPS operation and is capable of convergence in the presence of load transients or other disturbances. Experimental results are presented for various power stage configurations demonstrating close matches between monitored and expected crossover frequencies and phase margins.
Keywords :
"Band pass filters","Monitoring","Converters","Detectors","Digital filters","Switched-mode power supply","Frequency measurement"
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 2008. PESC 2008. IEEE
ISSN :
0275-9306
Print_ISBN :
978-1-4244-1667-7
Electronic_ISBN :
2377-6617
Type :
conf
DOI :
10.1109/PESC.2008.4592037
Filename :
4592037
Link To Document :
بازگشت