Title :
Capacitive coupling clamp
Author :
Slavko Radman;Iva Bacic;Kresimir Malaric
Author_Institution :
Dept. of Wireless Communication, Faculty of Electrical Engineering and Computing, Unska 3, 10 000 Zagreb, Croatia
Abstract :
This paper reports on a great area of electromagnetic compatibility. Special attention is given to measurement of electromagnetic interference established via the cable. A capacitive coupling clamp that conforms to requirements of ISO 64000-4-4 is built for measuring the resistance of three different cables (a twisted pair, RG - 58A/U and RG - 213/U) to external sources of continuous electromagnetic waves. The result is comparison of resistance to external interference of named cables.
Keywords :
"Clamps","Electrical resistance measurement","Electromagnetic measurements","Cables","Roentgenium","Electromagnetic compatibility","Electromagnetic interference","Electromagnetic coupling","ISO standards","Electromagnetic scattering"
Conference_Titel :
Software, Telecommunications and Computer Networks, 2008. SoftCOM 2008. 16th International Conference on
Print_ISBN :
978-953-6114-97-9
DOI :
10.1109/SOFTCOM.2008.4669455