• DocumentCode
    3631097
  • Title

    Accurate Time Constant of Random Telegraph Signal Extracted by a Sufficient Long Time Measurement in Very Large-Scale Array TEG

  • Author

    T. Fujisawa;K. Abe;S. Watabe;N. Miyamoto;A. Teramoto;S. Sugawa;T. Ohmi

  • Author_Institution
    Graduate School of Engineering, Tohoku University, Aza-Aoba 6-6-10, Aramaki, Aoba-ku, Sendai 980-8579, Japan. E-mail: fujisawa@fff.niche.tohoku.ac.jp
  • fYear
    2009
  • Firstpage
    19
  • Lastpage
    24
  • Abstract
    To suppress Random Telegraph Signal (RTS) noise in MOSFETs, it is necessary to understand the phenomena of RTS. We can extract the accurate time constant in RTS noise by measuring a huge number of MOSFETs during a long time. Time constant is useful to obtain the energy level. In this paper, we demonstrated the statistical and accurate measurement method of the time constant of RTS by a sufficient long measuring in very large-scale array TEG.
  • Keywords
    "Telegraphy","Time measurement","Large-scale systems","MOSFETs","Integrated circuit measurements","Voltage","Shift registers","Switches","Energy states","Insulation"
  • Publisher
    ieee
  • Conference_Titel
    Microelectronic Test Structures, 2009. ICMTS 2009. IEEE International Conference on
  • ISSN
    1071-9032
  • Print_ISBN
    978-1-4244-4259-1
  • Electronic_ISBN
    2158-1029
  • Type

    conf

  • DOI
    10.1109/ICMTS.2009.4814601
  • Filename
    4814601