DocumentCode :
3631835
Title :
A method of the BJT transient thermal impedance measurement with double junction calibration
Author :
J. Zarebski;K. Gorecki
Author_Institution :
Dept. of Radioelectron., Maritime Univ. Gdynia, Poland
fYear :
1995
Firstpage :
80
Lastpage :
82
Abstract :
In the paper a new method of the transient thermal impedance measurement of the bipolar transistor (BJT) is presented. This method is based on the conception of the double calibration of the thermosensitive emitter junction at a small collector current and under the condition of the heating power dissipated in the device, respectively. The method presented belongs to the methods making use of the heating curve, but it is simpler (faster) in realisation than the standard methods.
Keywords :
"Impedance measurement","Calibration","Power measurement","Pulse measurements","Time measurement","Heating","Current measurement","Temperature","Cooling","Measurement standards"
Publisher :
ieee
Conference_Titel :
Semiconductor Thermal Measurement and Management Symposium, 1995. SEMI-THERM XI., Eleventh Annual IEEE
ISSN :
1065-2221
Print_ISBN :
0-7803-2434-X
Type :
conf
DOI :
10.1109/STHERM.1995.512055
Filename :
512055
Link To Document :
بازگشت