Title :
Comparison of neutron detection efficiency using a He-3 counter and a Boron-10 loaded liquid scintillator EJ309B5
Author :
L. Swiderski;M. Moszynski;D. Wolski;J. Iwanowska;T. Szczesniak;G. Pausch;C. Plettner;J. Stein;P. Schotanus;C. Hurlbut
Author_Institution :
Soltan Institute for Nuclear Studies, Otwock-Swierk, PL-05-400 Poland
Abstract :
Performance of a He-3 counter and a B-10 loaded liquid scintillator EJ309B5 has been studied in terms of neutron detection efficiency. The measurements were carried out in a mixed field of neutron and gamma radiation from an intense (~106 neutrons/s/47t) 252Cf source. The response of both detectors to background and high intensity gamma radiation (~100 μSv/h at a detector) from a 60Co source has been measured to establish background count rate and gamma rays cut-off point, respectively. A method to compare the performance of various neutron detectors for border monitoring was proposed. The analysis showed that the properties of a He-3 counter are significantly better than that of EJ309B5. However, it has been pointed out how to improve the performance of a liquid scintillator in order to fulfill standards for neutron detection at borders.
Keywords :
"Radiation detectors","Testing","Gamma rays","Monitoring","Gamma ray detection","Gamma ray detectors","Nuclear and plasma sciences","Neutron spin echo","Laboratories","Particle beams"
Conference_Titel :
Nuclear Science Symposium Conference Record (NSS/MIC), 2009 IEEE
Print_ISBN :
978-1-4244-3961-4
DOI :
10.1109/NSSMIC.2009.5401557