DocumentCode
3635515
Title
Experimental analysis of electric parameters of a 100 t UHP electric arc furnace
Author
Adrian Ioan Toma;Gabriel Nicolae Popa;Angela Iagăr;Sorin Ioan Deaconu
Author_Institution
ArcelorMittal Hunedoara S.A., Iancu de Hunedoara Square, no.1, Hunedoara, Romania
fYear
2010
fDate
3/1/2010 12:00:00 AM
Firstpage
919
Lastpage
924
Abstract
This paper presents a study of power quality problems created by a UHP electric arc furnace (EAF) operation at power system. We are analyzing an electric arc furnace of 100 t capacity used for steel melting, and the related steel treatment installation. The measurements have been made using the CA8334 three-phase power quality analyser. Experimental results show that the EAF are a substantial source of electric disturbances, such as voltage fluctuations, flicker, harmonics, and unbalance between phases. Improvement of the energetic performances of an electric arc furnace imposes a careful technical and economical analysis, for choosing the possible solutions for balancing the load on phases, improving the wave forms (current and voltage) and improving the power factor.
Keywords
"Furnaces","Power quality","Steel","Voltage fluctuations","Power system analysis computing","Power system measurements","Power measurement","Power system harmonics","Power generation economics","Performance analysis"
Publisher
ieee
Conference_Titel
Industrial Technology (ICIT), 2010 IEEE International Conference on
Print_ISBN
978-1-4244-5695-6
Type
conf
DOI
10.1109/ICIT.2010.5472563
Filename
5472563