Title :
Stator damper winding and electromagnetic parameters of turbogenerators
Author :
Kristina Celio;Martin Dadic;Velimir Vrzic
Author_Institution :
Ministry of economy, Labor and Entrepreneurship Ulica grada Vukovara 78, 10000 Zagreb
Abstract :
The increase of the load in specific active parts of modern turbogenerators causes higher local heating, higher magnetic leakage, increased forces of the electromagnetic origin and the increased acoustic noise level. Stator damper winding is an active cage-shaped constructive element positioned at the outer stator core diameter. Its influence has been investigated using numerical methods, since classical analytic model according to the two-axis theory and Park´s equations is not applicable in this particular case.
Keywords :
"Stator windings","Turbogenerators","Bars","Electromagnetic forces","Machine windings","Acoustic noise","Stator cores","Joining processes","Packaging machines","Conducting materials"
Conference_Titel :
Industrial Technology (ICIT), 2010 IEEE International Conference on
Print_ISBN :
978-1-4244-5695-6
DOI :
10.1109/ICIT.2010.5472766