DocumentCode
3636718
Title
Control circuit for active power filter with an instantaneous reactive power control algorithm modification
Author
Krzysztof Piotr Sozański
Author_Institution
Faculty of Electrical Engineering, Computer Science and Telecommunications, University of Zielona Gó
fYear
2010
Firstpage
230
Lastpage
233
Abstract
This paper describes a proposal for modifications to an active power filter using a control circuit based on an instantaneous reactive power control algorithm. Such a control circuit has been realized using a fixed-point digital signal processor. The modification was made using an APF based on an old fixed-point TMS320C50 digital signal processor. Some illustrative, experimental results are also presented in the paper.
Keywords
"Circuits","Active filters","Reactive power control","Signal processing algorithms","Voltage","Digital signal processors","Power harmonic filters","Sampling methods","Frequency synchronization","Telecommunication control"
Publisher
ieee
Conference_Titel
Nonsinusoidal Currents and Compensation (ISNCC), 2010 International School on
Print_ISBN
978-1-4244-5436-5
Type
conf
DOI
10.1109/ISNCC.2010.5524480
Filename
5524480
Link To Document