• DocumentCode
    3636718
  • Title

    Control circuit for active power filter with an instantaneous reactive power control algorithm modification

  • Author

    Krzysztof Piotr Sozański

  • Author_Institution
    Faculty of Electrical Engineering, Computer Science and Telecommunications, University of Zielona Gó
  • fYear
    2010
  • Firstpage
    230
  • Lastpage
    233
  • Abstract
    This paper describes a proposal for modifications to an active power filter using a control circuit based on an instantaneous reactive power control algorithm. Such a control circuit has been realized using a fixed-point digital signal processor. The modification was made using an APF based on an old fixed-point TMS320C50 digital signal processor. Some illustrative, experimental results are also presented in the paper.
  • Keywords
    "Circuits","Active filters","Reactive power control","Signal processing algorithms","Voltage","Digital signal processors","Power harmonic filters","Sampling methods","Frequency synchronization","Telecommunication control"
  • Publisher
    ieee
  • Conference_Titel
    Nonsinusoidal Currents and Compensation (ISNCC), 2010 International School on
  • Print_ISBN
    978-1-4244-5436-5
  • Type

    conf

  • DOI
    10.1109/ISNCC.2010.5524480
  • Filename
    5524480