• DocumentCode
    3637088
  • Title

    Two-phase active thermal control systems for spacecrafts

  • Author

    Ing Youn Chen;M.-C. Chyu

  • Author_Institution
    Dept. of Mech. Eng., Nat. Yunlin Inst. of Technol., Taiwan
  • Volume
    2
  • fYear
    1996
  • Firstpage
    1488
  • Abstract
    The lower mass flow rate for a two-phase system compared with that of a single-phase system results in benefits in terms of reduced pumping power, system size and weight. The design and testing of two-phase fluid thermal loops for future large spacecraft has been conducted at NASA Johnson Space Center since 1982. This report presents a review and summary of the two-phase thermal system test results of Grumman Thermal Bus System, Lockheed Ground Test Unit and Boeing/Sundstrand Ground Test Article (GTA) Space Station prototypes, which were tested from 1987 to 1993. The thermal-hydraulic performances of the two-phase thermal buses are briefly described and comparison of three bus test results is made. The advantages of the selected thermal bus (GTA) are described.
  • Keywords
    "Control systems","Space vehicles","System testing","Fluid flow control","Pumps","Thermal conductivity","NASA","Space stations","Prototypes","Performance evaluation"
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Engineering Conference, 1996. IECEC 96., Proceedings of the 31st Intersociety
  • ISSN
    1089-3547
  • Print_ISBN
    0-7803-3547-3
  • Type

    conf

  • DOI
    10.1109/IECEC.1996.553948
  • Filename
    553948