  • Title

    Influence of mounting temperature probes on the excitation winding on its temperature field

  • Author

    Zlatko Hanić;Marinko Kovačić;Mario Vražić

  • Author_Institution
    Department of Electrical Machines and Automation at the Faculty of Electrical Engineering and Computing at the University of Zagreb, Croatia
  • fYear
    2010
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Accurate and reliable information about the temperature of the synchronous generator excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it was decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA, 50 Hz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured before and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy.