Performance evaluation of a new hybrid-modulation scheme for high-frequency-ac-link inverter: Applications for PV, wind, fuel-cell, and DER/storage applications
Author
Sudip K. Mazumder;Akshay K. Rathore
Author_Institution
Laboratory for Energy and Switching Electronics Systems, Electrical and Computer Engineering Department, University of Illinois at Chicago, 60660, USA
fYear
2010
Firstpage
2529
Lastpage
2534
Abstract
Advances in SiC (and upcoming GaN) based power semiconductor devices, high-permeability nanocrystalline high-frequency (HF) transformers, and advanced processing and sensing capabilities have paved the way for HF-ac-link (HFACL) based isolated inverter systems that have wide applications encompassing high-power (HP) renewable- and alternative-energy systems (e.g. photovoltaic, wind, fuel-cell energy systems), DG/DER applications, active filters, energy storage, and compact defense power-conversion modules. Unlike conventional Si-based low-frequency HP systems, the switches in these applications need to operate at frequencies 20–50 kHz instead of being limited by conventional HP devices (e.g. Si-based IGCTs, GTOs). Additionally, HFACL systems eliminate the intermediate dc-link filters, which are needed in fixed-dc-link (FDCL) approaches. However, one of the challenges of such HP and HF approaches is switching loss. In that regard, this paper demonstrates, under scaled-power condition, the efficacy of a recently-outlined and patented hybrid-modulation (HM) scheme, which can reduce the switching losses of the ac/ac converter of a HFACL inverter by up to 66%. This also leads to improved voltage utilization as compared to state-of-the-art space-vector-modulation (SVM) schemes and reduction in device current stress. We also demonstrate that, even though the HM based HFACL approach works without a dc-link capacitor, the output THD of the inverter is not worse than the SVM based FDCL inverter. The HM scheme is unlike all reported discontinuous-modulation (DM) schemes where the input to the final stage of the inverter is a dc and not a pulsating-dc; further, in the HM scheme, switches in 2 legs of the ac/ac converter do not change state in a 60° cycle and switches in any one leg do not change state for an overall 240°. In contrast, for a conventional DM scheme, at most switches of 1 leg of the ac/ac converter do not change stage in a 60° or 120° cycle.
Keywords
"Modulation","Converters","Inverters","Bridge circuits","Support vector machines","Rectifiers","Topology"
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2010 IEEE
Print_ISBN
978-1-4244-5286-6
Type
conf
DOI
10.1109/ECCE.2010.5617965
Filename
5617965
Link To Document