DocumentCode :
3638940
Title :
Independent Component Analysis (ICA) methods for neonatal EEG artifact extraction: Sensitivity to variation of artifact properties
Author :
Nadica Miljković;Vladimir Matić;Sabine Van Huffel;Mirjana B. Popović
Author_Institution :
University of Belgrade, Faculty of Electrical Engineering and Fatronik Serbia, Bulevar kralja Aleksandra 73, Belgrade, Serbia
fYear :
2010
Firstpage :
19
Lastpage :
21
Abstract :
Independent Component Analysis (ICA) is becoming an accepted technique for artifact removal. Nevertheless, there is no consensus about appropriate methods for different applications. This study presents a comparison of common ICA methods: RobustICA, SOBI, JADE, and BSS-CCA, for extraction of ECG artifacts from EEG signal. Algorithms were applied to the data created by superimposing artifact free real-life neonatal EEG and synthetic ECG. Their sensitivity to variation of noise property was compared: we examined variability of Spearman correlation coefficients (SCC) for various Heart Rates (HR) in each of ICA methods. Results show that SOBI and BSS-CCA methods were less sensitive than RobustICA and JADE to artifact alterations (mean SCCs were 0.85 and 0.85 compared to 0.80 and 0.73, respectively) being quite successful in source signal extraction.
Keywords :
"Electroencephalography","Electrocardiography","Pediatrics","Algorithm design and analysis","Correlation","Robustness","Independent component analysis"
Publisher :
ieee
Conference_Titel :
Neural Network Applications in Electrical Engineering (NEUREL), 2010 10th Symposium on
Print_ISBN :
978-1-4244-8821-6
Type :
conf
DOI :
10.1109/NEUREL.2010.5644041
Filename :
5644041