• DocumentCode
    3641929
  • Title

    Three-phase regenerative electronic load to test shunt power conditioners

  • Author

    C. Roncero-Clemente;M. I Milanes-Montero;V. M. Minambres-Marcos;E. Romero-Cadaval

  • Author_Institution
    Power Electrical &
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    178
  • Lastpage
    183
  • Abstract
    A 3-phase regenerative electronic load to test shunt equipments such as active power filters and power conditioners at high power levels is presented in this paper. The electronic load is composed by two inverters with a common DC-bus. One inverter draws from the grid a configurable load current with the harmonic and imbalance desired levels, and the other one is used to inject the energy into the grid trying to minimize the losses, while the active filter performance is being tested. The control strategies and the current controller for both inverters are explained. Simulations and experimental results showing the proper operation of the electronic load to test shunt power conditioners are presented.
  • Keywords
    "Inverters","Harmonic analysis","Load modeling","Power harmonic filters","Topology","Recycling"
  • Publisher
    ieee
  • Conference_Titel
    Compatibility and Power Electronics (CPE), 2011 7th International Conference-Workshop
  • Print_ISBN
    978-1-4244-8806-3
  • Type

    conf

  • DOI
    10.1109/CPE.2011.5942228
  • Filename
    5942228