• DocumentCode
    3643449
  • Title

    Development of an ASIC for 2-D readout of Gas Electron Multiplier detectors

  • Author

    Władyslaw Dąbrowski; Tomasz Fiutowski; Bartosz Mindur; Piotr Wiącek; Alicja Zielińska

  • Author_Institution
    Faculty of Physics and Applied Computer Science, AGH University of Science and Technology, Krakó
  • fYear
    2011
  • fDate
    6/1/2011 12:00:00 AM
  • Firstpage
    303
  • Lastpage
    308
  • Abstract
    This paper describes an Application Specific Integrated Circuit (ASIC) to be used for readout of large area (30 × 30cm2) Gas Electron Multiplier (GEM) detector. The GEMROC design follows the concept of the previously designed MSGCROC ASIC for 2-D readout of Micro Strip Gas Chamber (MSGC) detector. The architecture and parameters are determined by requirements of 2-D GEM detector used in the Proton Range Radiography system. The circuit has been designed in 0.35μm CMOS process. The basic functionality and parameters have been evaluated using the testability functions implemented in the ASIC design. In the paper we present the architecture of the ASIC, designs of selected circuits, and examples of test results.
  • Keywords
    "Application specific integrated circuits","Detectors","Noise","Capacitors","Capacitance","Timing","Strips"
  • Publisher
    ieee
  • Conference_Titel
    Mixed Design of Integrated Circuits and Systems (MIXDES), 2011 Proceedings of the 18th International Conference
  • Print_ISBN
    978-1-4577-0304-1
  • Type

    conf

  • Filename
    6015930