DocumentCode
3645909
Title
First results from the online radiation dose monitoring system in ATLAS experiment
Author
I. Mandic;V. Cindro;M. Deliyergiyev;A. Gorišek;G. Kramberger;M. Mikuž;J. Hartert;S. Franz;I. Dawson;P. S. Miyagawa;L. Nicolas
Author_Institution
Jož
fYear
2011
Firstpage
1107
Lastpage
1112
Abstract
High radiation doses which will accumulate in components of ATLAS experiment during data taking will cause damage to detectors and readout electronics. It is therefore important to continuously monitor the doses to estimate the level of degradation caused by radiation. Online radiation monitoring system measures ionizing dose in SiO2 and fluences of 1-MeV(Si) equivalent neutrons and thermal neutrons at several locations in ATLAS detector. In this paper measurements collected during two years of ATLAS data taking are presented and compared to predictions from radiation background simulations.