Title :
Experimental analysis for plate-type electrostatic precipitators with three sections
Author :
Gabriel Nicolae Popa;Sorin Ioan Deaconu;Iosif Popa;Corina Maria Diniş
Author_Institution :
Department of Electrotechnical Engineering and Industrial Informatics, Politehnica University of Timiş
fDate :
5/1/2012 12:00:00 AM
Abstract :
The plate-type electrostatic precipitators have been use by industry applications as the preferred method for controlling pollution with dust particles. This article is presenting an experimental analysis of the current-voltage characteristics, dust emissions and powers absorbed by the sources of some three-section electrostatic precipitators from a thermo-electrical power plant. Due to complex phenomena, at industrial electrostatic precipitators the current-voltage characteristics from the sections are permanently modifying, which makes impossible the mathematic modelling. It was not noticed a mathematical connection between the evolution of the dust emissions and powers absorbed by the supply sources.
Keywords :
"Current measurement","Voltage measurement","Discharges (electric)","Current-voltage characteristics","Electrostatic precipitators","Power supplies","Fault diagnosis"
Conference_Titel :
Optimization of Electrical and Electronic Equipment (OPTIM), 2012 13th International Conference on
Print_ISBN :
978-1-4673-1650-7
DOI :
10.1109/OPTIM.2012.6231779