DocumentCode
3647905
Title
Modeling of metallic cables´ attenuation for extreme temperatures
Author
Jiří Vodrážka;Pavel Lafata
Author_Institution
Department of Telecommunication Engineering, Faculty of Electrical Engineering, Czech Technical University in Prague, Czech Republic
fYear
2012
fDate
7/1/2012 12:00:00 AM
Firstpage
277
Lastpage
281
Abstract
The transmission parameters of metallic cables and lines, such as attenuation, crosstalk, etc., are significantly influenced by external parameters and conditions, e.g. temperature, external deformations, bending of metallic cable, moisture, glaze ice on the cable, etc. There are already several models to describe some of these phenomena, but these models are usually valid only for a limited range. This article deals with the influence of extreme temperatures (burning) on transmission parameters of metallic cables, especially on its attenuation. This paper contains the description of performed experimental measurement for specific metallic cable and it also presents derived mathematical models and simulations.
Keywords
"Temperature measurement","Attenuation","Cable TV","Fires","Furnaces","Electrical resistance measurement","Temperature dependence"
Publisher
ieee
Conference_Titel
Telecommunications and Signal Processing (TSP), 2012 35th International Conference on
Print_ISBN
978-1-4673-1117-5
Type
conf
DOI
10.1109/TSP.2012.6256298
Filename