Title :
Breakdown voltages in SF/sub 6/+argon mixtures under nonuniform electrostatic fields
Author :
H.R. Hiziroglu;M.S. Dincer;T.D. Nguyen
Author_Institution :
Dept. of Electr. & Comput. Eng., GMI Eng. & Manage. Inst., Flint, MI, USA
Abstract :
This study presents the experimental findings in SF/sub 6/+Ar binary mixtures under nonuniform electrostatic fields for different contents of SF/sub 6/ in the mixture. The discharge inception and breakdown voltages were monitored at 50 kPa and 100 kPa of total gas pressure. The breakdown strength of SF/sub 6/+Ar has increased dramatically with small percentage of SF/sub 6/. However, for higher SF/sub 6/ contents, the breakdown voltages did increase monotonically but not dramatically, and indicated a more pronounced corona stabilization activity.
Keywords :
"Breakdown voltage","Argon","Electrostatics","Electrodes","Corona","Nonuniform electric fields","Electric breakdown","Electronic equipment testing","Steel","Monitoring"
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 1997. IEEE 1997 Annual Report., Conference on
Print_ISBN :
0-7803-3851-0
DOI :
10.1109/CEIDP.1997.641140