• DocumentCode
    3649793
  • Title

    Breakdown voltages in SF/sub 6/+argon mixtures under nonuniform electrostatic fields

  • Author

    H.R. Hiziroglu;M.S. Dincer;T.D. Nguyen

  • Author_Institution
    Dept. of Electr. & Comput. Eng., GMI Eng. & Manage. Inst., Flint, MI, USA
  • Volume
    2
  • fYear
    1997
  • Firstpage
    579
  • Abstract
    This study presents the experimental findings in SF/sub 6/+Ar binary mixtures under nonuniform electrostatic fields for different contents of SF/sub 6/ in the mixture. The discharge inception and breakdown voltages were monitored at 50 kPa and 100 kPa of total gas pressure. The breakdown strength of SF/sub 6/+Ar has increased dramatically with small percentage of SF/sub 6/. However, for higher SF/sub 6/ contents, the breakdown voltages did increase monotonically but not dramatically, and indicated a more pronounced corona stabilization activity.
  • Keywords
    "Breakdown voltage","Argon","Electrostatics","Electrodes","Corona","Nonuniform electric fields","Electric breakdown","Electronic equipment testing","Steel","Monitoring"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1997. IEEE 1997 Annual Report., Conference on
  • Print_ISBN
    0-7803-3851-0
  • Type

    conf

  • DOI
    10.1109/CEIDP.1997.641140
  • Filename
    641140