DocumentCode :
3649871
Title :
Myoelectric Algorithm for Knee Angle Estimation Using Proprioceptive Data and a Compatibility Test
Author :
A. López ;J.L. Azevedo de Carvalho;A. Ferreira da Rocha;F.A. de_Oliveira Nascimento;G. Araújo ;A.F. Ruiz Olaya
Author_Institution :
Med. Biophys. Center, Univ. of Oriente, Santiago de Cuba, Cuba
fYear :
2012
Firstpage :
177
Lastpage :
180
Abstract :
This article presents a method to estimate the knee angle based on data fusion for transfemoral leg prostheses control, using information from two electromyographic signals, two gyroscope sensors and one electrogoniometer channel. This information is processed in three stages: feature extraction using cepstral coefficients and the myoelectric signal entropy, pattern classification using a perceptron neural network and data fusion from a Kalman filter. A compatibility test is introduced based on Mahalanobis distance with the aim to detect possible artifacts to come from the estimated angle at the neural network output. The method was tested in healthy subjects, and the results were compared with another work that was based solely on myoelectric signals. The results showed that the use of additional information related to proprioception improves the precision of the knee joint angle estimation, and reduces artifacts.
Keywords :
"Data integration","Knee","Joints","Sensors","Cepstral analysis","Algorithm design and analysis","Estimation"
Publisher :
ieee
Conference_Titel :
Andean Region International Conference (ANDESCON), 2012 VI
Print_ISBN :
978-1-4673-4427-2
Type :
conf
DOI :
10.1109/Andescon.2012.48
Filename :
6424145
Link To Document :
بازگشت