DocumentCode
3652605
Title
The Next Generation Radiation Monitor- NGRM
Author
L. Desorgher;W. Hajdas;I. Britvitch;K. Egli;X. Guo;Y. Luo;F. Chastellain;C. Pereira;R. Muff;D. Boscher;G. Maehlum;D. Meier
Author_Institution
Paul Scherrer Institute, PSI, 5232 Villigen PSI, Switzerland
fYear
2013
Firstpage
1
Lastpage
6
Abstract
The ESA Next Generation Radiation Monitor (NGRM) will be the successor of the ESA Standard Radiation Environment Monitor (SREM) that is still measuring near-Earth and interplanetary space radiation environment onboard 6 different spacecrafts. NGRM will measure protons from 2 MeV up to 200 MeV, electrons from 100keV up to 7MeV, as well as LET spectrum of ions. Compared to SREM, NGRM will provide a much better energy resolution, will be smaller (<1L), lighter (<1kg) and consume less energy (<1W). In this paper we describe the detection concept of the NGRM and present the detailed Monte Carlo analysis of the performance of the NGRM detector system.
Keywords
"Detectors","Protons","Orbits","Application specific integrated circuits","Channel estimation","Aluminum","Energy measurement"
Publisher
ieee
Conference_Titel
Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2013 IEEE
Type
conf
DOI
10.1109/NSSMIC.2013.6829497
Filename
6829497
Link To Document