DocumentCode
3656619
Title
Turn to turn fault analysis of three phase PMSG for different rotor air gap
Author
Sanket Parashar;Rakesh Kumar Srivastava
Author_Institution
Electrical Engineering, Indian Institute of Technology (BHU) Varanasi, India
fYear
2015
fDate
5/1/2015 12:00:00 AM
Firstpage
114
Lastpage
120
Abstract
This paper presents an approach to study the performance of Three phase Permanent Magnet Synchronous Generator for different rotor air gap during inter-turn fault. Winding Function Theory has been used for study of abnormal behavior in the machine during winding fault. Winding Function Theory (WFT) provides an easier way to model winding inductances of machine under healthy and unhealthy conditions. Mathematical modeling has been done to get the expressions relating effect of air gap to various performance parameters of generator during fault. Results obtained by mathematical modeling have been thoroughly studied and validated using experimental results.
Keywords
"Circuit faults","Windings","Generators","Coils","Transient analysis","Mathematical model","Stators"
Publisher
ieee
Conference_Titel
Power Engineering, Energy and Electrical Drives (POWERENG), 2015 IEEE 5th International Conference on
Print_ISBN
978-1-4673-7203-9
Electronic_ISBN
2155-5532
Type
conf
DOI
10.1109/PowerEng.2015.7266304
Filename
7266304
Link To Document