• DocumentCode
    3656619
  • Title

    Turn to turn fault analysis of three phase PMSG for different rotor air gap

  • Author

    Sanket Parashar;Rakesh Kumar Srivastava

  • Author_Institution
    Electrical Engineering, Indian Institute of Technology (BHU) Varanasi, India
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    114
  • Lastpage
    120
  • Abstract
    This paper presents an approach to study the performance of Three phase Permanent Magnet Synchronous Generator for different rotor air gap during inter-turn fault. Winding Function Theory has been used for study of abnormal behavior in the machine during winding fault. Winding Function Theory (WFT) provides an easier way to model winding inductances of machine under healthy and unhealthy conditions. Mathematical modeling has been done to get the expressions relating effect of air gap to various performance parameters of generator during fault. Results obtained by mathematical modeling have been thoroughly studied and validated using experimental results.
  • Keywords
    "Circuit faults","Windings","Generators","Coils","Transient analysis","Mathematical model","Stators"
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering, Energy and Electrical Drives (POWERENG), 2015 IEEE 5th International Conference on
  • Print_ISBN
    978-1-4673-7203-9
  • Electronic_ISBN
    2155-5532
  • Type

    conf

  • DOI
    10.1109/PowerEng.2015.7266304
  • Filename
    7266304