DocumentCode
3658986
Title
Energy conservation using variable frequency drives of a humidification plant in a textile mill
Author
Bhavana MB;Vishwanath Hegde
Author_Institution
Dept. of Electrical and Electronics Engineering, Malnad College of Engineering, Hassan, Karnataka, India
fYear
2015
Firstpage
90
Lastpage
94
Abstract
Humidification plant in a textile industry is one of the major power consumers due to its continuous operation for maintaining required Relative Humidity (RH) and temperature of spinning plant to increase the quality of yarn. The traditional method of operation of induction motors in humidification plant was effective, but not energy efficient. To overcome this problem, the emerging trend is the widespread adoption of variable frequency drives (VFD) which can offer potential energy savings in a system by allowing continuous process of speed control. In this paper, modeling, simulation and performance analysis of `Open loop and closed loop speed control of induction motor using Variable frequency drive´ in MATLAB/Simulink and the Performance Verification of humidification plant in a textile industry where VFDs are installed very recently are presented.
Keywords
"Induction motors","Velocity control","Textile industry","Variable speed drives","Software packages","Power demand","Pulse width modulation"
Publisher
ieee
Conference_Titel
Power and Advanced Control Engineering (ICPACE), 2015 International Conference on
Type
conf
DOI
10.1109/ICPACE.2015.7274923
Filename
7274923
Link To Document