• DocumentCode
    3659048
  • Title

    Studies on the electrical characteristics of a thermal power plant Electrostatic Precipitator

  • Author

    M.D. Sharath Kumar;A.D. Srinivasan

  • Author_Institution
    AT&
  • fYear
    2015
  • Firstpage
    429
  • Lastpage
    435
  • Abstract
    An Electrostatic Precipitator (ESP) is the most efficient device to capture fly ash. The performance of an ESP can be determined by Voltage-Current (V-I) characteristics which will reflect upon the collection efficiency. In this paper, a new approach based on Finite Difference Method (FDM) has been utilized for the simulation of V-I characteristics of an ESP under clean air and dust loaded conditions. The present simulation work with FDM is computationally simple as one grid is employed for solving the Poisson´s equation and Current continuity equation which gives sufficiently accurate results. Further, V-I measurements for one of the ESPs were conducted by the author at Raichur Thermal Power Station (RTPS) in India and the simulated results were compared with the measured ones. The results for clean air were validated with the published experimental data and the present method has been compared with the other methods.
  • Keywords
    "Mathematical model","Wires","Atmospheric modeling","Load modeling","Space charge","Fly ash","Poisson equations"
  • Publisher
    ieee
  • Conference_Titel
    Power and Advanced Control Engineering (ICPACE), 2015 International Conference on
  • Type

    conf

  • DOI
    10.1109/ICPACE.2015.7274986
  • Filename
    7274986