• DocumentCode
    3662670
  • Title

    Rubidium diffusion in microscale spectroscopy and slow light platforms

  • Author

    Matthieu Giraud-Carrier;Cameron Hill;Trevor Decker;Aaron R. Hawkins;Jennifer A. Black;Soren Almquist;Holger Schmidt

  • Author_Institution
    Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, United States
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    This paper presents an approach to quantifying the diffusion rate of rubidium in glass microchannels. These types of microchannels are often used in integrated systems (chip and fiber based) which utilize light and rubidium vapor interactions to produce quantum interference phenomena such as slow light. The test platforms reported here were made using glass capillaries connected to larger glass chambers through glassblowing. Rubidium diffusion was monitored in two different ways. First, fluorescence measurements were taken over time at different points down the length of the capillary. Second, optical absorption measurements were taken through the large glass chambers on either side of the capillaries. Results indicate that reaching measurable atomic densities in microscale geometries can take many days or even weeks.
  • Keywords
    "Rubidium","Glass","Reservoirs","Absorption","Fluorescence","Atomic measurements","Optical waveguides"
  • Publisher
    ieee
  • Conference_Titel
    Circuits and Systems (MWSCAS), 2015 IEEE 58th International Midwest Symposium on
  • Type

    conf

  • DOI
    10.1109/MWSCAS.2015.7282129
  • Filename
    7282129