• DocumentCode
    3664397
  • Title

    The development of transducer to detect partial discharge in XLPE cable based on electromagnetic coupling method

  • Author

    Xiaoli Hu;Yubing Duan;Xinyan Feng;Jun Yong;Bo Yang;Minglin Liu;Hailei Meng;Xiaobin Sun;Yiming Zhang

  • Author_Institution
    Shandong Elecrtic Power Research Institute, Ji´nan 250002, China
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    341
  • Lastpage
    344
  • Abstract
    The partial discharge is an important parameter to reflect the insulation condition of XLPE power cable. The electromagnetic coupling method is the most effective method to detect partial discharge in XLPE cable. Based on the electromagnetic coupling means, this paper designs and develops a kind of transducer to detect partial discharge in XLPE cable. According to the choice of the appropriate core material characteristic of partial discharge signal, a serial of model analysis and test have been performed to determine the integrating resistance and coiling number´s influence on amplitude-frequency characteristics of current transducer. The key parameters of the optimal integral resistance and the number of windings of the coil sensor is determined. The test in laboratory and the installation in the field have proved that the transducer has wide working frequency band and high sensitivity which meets the request of XLPE cable partial discharge detection.
  • Keywords
    "Transducers","Partial discharges","Power cables","Magnetic cores","Windings","Power cable insulation"
  • Publisher
    ieee
  • Conference_Titel
    Electronics Information and Emergency Communication (ICEIEC), 2015 5th International Conference on
  • Print_ISBN
    978-1-4799-7283-8
  • Type

    conf

  • DOI
    10.1109/ICEIEC.2015.7284554
  • Filename
    7284554