Abstract
The inflection point (POI) of the HTFP melting curve has been mainly applied as a reference point in comparisons of local temperature scales. It has also been proposed to serve as a lower limit to be set to the liquidus temperature. In this paper, we confine ourselves to the determination of the inflection points by a statistical method for the Co-C involved in InK-WP1. Details of the metod will be introduced in this paper.
Keywords
"Temperature measurement","Uncertainty","Fitting","Statistical analysis","Ink","Temperature distribution","Metals"