DocumentCode :
3670121
Title :
Depth sensor calibration by tracking an extended object
Author :
Florian Faion;Marcus Baum;Antonio Zea;Uwe D. Hanebeck
Author_Institution :
Intelligent Sensor-Actuator-Systems Laboratory (ISAS), Institute for Anthropomatics and Robotics, Karlsruhe Institute of Technology (KIT), Germany
fYear :
2015
Firstpage :
19
Lastpage :
24
Abstract :
In this paper, we propose a novel algorithm for automatically calibrating a network of depth sensors, based on a moving calibration object. The sensors may have non-overlapping fields of view in order to avoid interference. Two major challenges are discussed. First, depending on where the object is located relative to the sensor, the number and quality of the measurements strongly varies. Second, a single depth sensor observes the calibration object only from one side. Dealing with these challenges requires a simple calibration object as well as an algorithm that can deal with under-determined measurements of varying quality. A recursive Bayesian estimator is developed that determines the extrinsic parameters by measuring the surface of a moving cube with known pose. Our approach does not restrict the configuration of the network and requires no manual initialization or interaction. Ambiguities that are induced by the rotational cube symmetries are resolved by applying a multiple model approach. Besides synthetic evaluation we perform real data experiments and compare to state-of-the-art calibration.
Keywords :
"Calibration","Robot sensing systems","Three-dimensional displays","Noise measurement","Estimation","Mathematical model","Bayes methods"
Publisher :
ieee
Conference_Titel :
Multisensor Fusion and Integration for Intelligent Systems (MFI), 2015 IEEE International Conference on
Type :
conf
DOI :
10.1109/MFI.2015.7295739
Filename :
7295739
Link To Document :
بازگشت