DocumentCode
3671036
Title
Design of a 2 MV, 3 Ω flash radiographic driver — Charybdis
Author
A. Jones;D. Goude;J. Macdonald;T. Williams
Author_Institution
Atomic Weapons Establishment, Aldermaston, Berkshire, UK
fYear
2015
fDate
5/1/2015 12:00:00 AM
Firstpage
1
Lastpage
6
Abstract
In order to deliver higher fidelity flash radiography images of explosive trials, AWE requires a new generation of Pulsed Power sources. In the design presented here, a 3.5 Ω water-filled Pulse Forming Line, charged by a 4.7 MV Marx generator, would deliver 2 MV to a Plasma-Filled Rod-Pinch diode. This design would dramatically exceed AWE´s ageing Mini-B performance in radiation fluence, resolution and x-ray spectrum.
Keywords
"Radiography","Switches","Plasmas","Generators","Explosives","Electric breakdown","Inductance"
Publisher
ieee
Conference_Titel
Pulsed Power Conference (PPC), 2015 IEEE
ISSN
2158-4915
Electronic_ISBN
2158-4923
Type
conf
DOI
10.1109/PPC.2015.7296935
Filename
7296935
Link To Document