• DocumentCode
    3671073
  • Title

    Development and test of a ∼800kV, ∼35 kA air insulated LTD pulser for radiography application

  • Author

    F. Bayol;J. Calvignac;R. Delplanque;C. Gaston;P. Mouly;K. Van de Wiel;S. Briscall;S. Hill;A. Jones;M. Sinclair;M. Weeks

  • Author_Institution
    ITHPP, Hameau de Drê
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    AWE is replacing its current Mevex X-ray machine (~800kV, 35kA, 60ns pulse) to improve reliability and maintainability. A design using a Linear Transformer Driver (LTD) insulated with dry air at atmospheric pressure has been developed by ITHPP. A testbed using 3 cavities, made from 2 bricks of two GA35460M 8nF, 100kV capacitors, a multigap multichannel switch and a magnetic core, has been developed and extensively tested [1]. This led to the development of the full generator that uses 17 cavities in series to produce an 800kV output voltage on a vacuum insulated line and a 23-25Ω diode. The ~4.3m long inner stalk is cantilevered by the back of the pulser and is positioned by a 3 point adjustable support. This setting is completed by 2 internal tensioning cables to compensate for flexing and provide fine adjustment of the diode end. The assembly of the generator has been done on the 1st half of 2015. The machine can be operated with negative and positive polarity outputs to satisfy operational requirements given by AWE. The tests results of this generator in both polarities are presented in terms of output performances. The reproducibility and reliability of the full system is also analyzed.
  • Keywords
    "Cavity resonators","Generators","Switches","Cathodes","Voltage measurement","Light emitting diodes","Insulation"
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference (PPC), 2015 IEEE
  • ISSN
    2158-4915
  • Electronic_ISBN
    2158-4923
  • Type

    conf

  • DOI
    10.1109/PPC.2015.7296972
  • Filename
    7296972