• DocumentCode
    3671088
  • Title

    Gas selection and flow optimization for A 1 kHz trigatron spark gap

  • Author

    W. Hunter Cravey;David V. Reale;Raymundo S. Garcia;Jared M. Johnson;Andreas A. Neuber;James C. Dickens;John J. Mankowski

  • Author_Institution
    Dept. of Electr. Eng., Texas Tech Univ., Lubbock, TX, USA
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    3
  • Abstract
    This paper discusses the design of a gas flow system for a 1 kHz repetition rate trigatron based spark gap. The system requires a flow rate high enough to clear the gas from the gap in under 1 ms while also maintaining the required operating pressure. The gap is a trigatron based design with an alumina insulated tungsten trigger pin. A 20 kV positive polarity pulse, with a 20 ns risetime, is applied to trigger the main gap which is charged to -40 kV. A brass guard ring is employed to shield the walls of the containment structure from contaminants in order to achieve a longer operational lifetime. Dry air and Nitrogen gasses are tested at various pressures and flow rates. Design considerations, such as inlet and outlet sizing and gap geometry, are taken into account to ensure a high air flow is achieved between the electrodes.
  • Keywords
    "Decision support systems","Government"
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference (PPC), 2015 IEEE
  • ISSN
    2158-4915
  • Electronic_ISBN
    2158-4923
  • Type

    conf

  • DOI
    10.1109/PPC.2015.7296987
  • Filename
    7296987