Title :
Measured sensitivity of the first mark II phased array feed on an ASKAP antenna
Author :
A. P. Chippendale;A. J. Brown;R. J. Beresford;G. A. Hampson;A. Macleod;R. D. Shaw;M. L. Brothers;C. Cantrall;A. R. Forsyth;S. G. Hay;M. Leach
Author_Institution :
CSIRO Astronomy and Space Science, PO Box 76, Epping, NSW 1710, Australia
Abstract :
This paper presents the measured sensitivity of CSIRO´s first Mk. II phased array feed (PAF) on an ASKAP antenna. The Mk. II achieves a minimum system-temperature-over-efficiency Tsys/η of 78 K at 1.23 GHz and is 95 K or better from 835 MHz to 1.8 GHz. This PAF was designed for the Australian SKA Pathfinder telescope to demonstrate fast astronomical surveys with a wide field of view for the Square Kilometre Array (SKA).
Keywords :
"Extraterrestrial measurements","Antenna measurements","Antenna arrays","Frequency measurement","Astronomy","Radio frequency"
Conference_Titel :
Electromagnetics in Advanced Applications (ICEAA), 2015 International Conference on
DOI :
10.1109/ICEAA.2015.7297174