DocumentCode
3672696
Title
Real-time arm tracking for HMI applications
Author
Matthew Masters;Luke Osborn;Nitish Thakor;Alcimar Soares
Author_Institution
Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21218
fYear
2015
fDate
6/1/2015 12:00:00 AM
Firstpage
1
Lastpage
4
Abstract
Limb tracking is an important aspect of human-machine interfaces (HMI). These systems, however, can often be limited by complex algorithms requiring significant processing power, obtrusive and immobile sensing techniques, and high costs. In this work, we utilize a sensor fusion algorithm implemented in commercial inertial measurement units (IMU) to combine accelerometer and gyroscope measurements in an effort to minimize computational requirements of the limb tracking system. In addition, previously developed methods were implemented to eliminate sensor drift by including information from a magnetometer. We tested the accuracy of our system by computing the root mean squared error (RMSE) of the true angle between the headings of two sensors and the estimate of that angle through quaternion-vector manipulations. An average RMSE of approximately 2.9° was achieved. Our limb tracking system is wearable, minimally complex, low-cost, and simple to use which has proven useful in multiple HMI applications discussed herein.
Keywords
"Quaternions","Sensor fusion","Real-time systems","Prosthetics","Trajectory","Target tracking"
Publisher
ieee
Conference_Titel
Wearable and Implantable Body Sensor Networks (BSN), 2015 IEEE 12th International Conference on
Type
conf
DOI
10.1109/BSN.2015.7299391
Filename
7299391
Link To Document