• DocumentCode
    3673721
  • Title

    New strategies for frequency measurement using high-speed video camera system

  • Author

    Blazej Kuhajda;Radek Martinek;Michal Kelnar;Jan Vanus;Petr Bilik

  • Author_Institution
    Department of Cybernetics and Biomedical Engineering, VSB-TU, FEI, 17. listopadu 15, 708 33 Ostrava-Poruba, Czech Republic
  • fYear
    2015
  • Firstpage
    125
  • Lastpage
    130
  • Abstract
    This paper describes the design, construction, and testing of a high speed cameras as a measuring sensor for position of a fast moving mechanical object. Position is evaluated by detecting the edges of the object. Datasets of these positions then becomes subject to frequency analysis aiming to determine oscillation. The functional prototype is based on virtual instrumentation making use of the LabVIEW developmental environment. The hardware part consists of a high speed video camera, PC with a camera-link frame-rabber. New method for evaluation of oscillation is suitable in range up to hundreds of hertz. The asset of suggested method is its contactless application. It can replace the most common contactless sensors.
  • Keywords
    "Cameras","Frequency measurement","Lenses","Oscillators","Calibration","Testing","Biomedical measurement"
  • Publisher
    ieee
  • Conference_Titel
    Applied Electronics (AE), 2015 International Conference on
  • ISSN
    1803-7232
  • Print_ISBN
    978-8-0261-0385-1
  • Type

    conf

  • Filename
    7301071