DocumentCode :
3674807
Title :
Affinity biosensors based on thin organic films on a metal microsystem support
Author :
M. Snejdarkova;L. Sokolikova;V. Tvarozek;I. Novotny;T. Hianik
Author_Institution :
Inst. of Animal Biochem. & Genetics, Acad. of Sci., Ivanka pri Dunaji, Slovakia
fYear :
1998
Firstpage :
367
Lastpage :
370
Abstract :
Protein films (PF) on gold microsystem support were used for construction affinity biosensor for detecting human IgE. Antigen Q-SwaHU/IgE was bound with cysteamine or with cystramine-bovine serum albumin (BSA) complex by means of glutaraldehyde and immobilized to the thin gold support working electrode by means of chemisorption. The interaction of IgE with affinity biosensor has been detected by means of conductance. Addition of IgE to the electrolyte contained biosensor with BSA resulted in decrease membrane conductance, which that with BSA resulted in increase of sensor conductance in logarithm shape. in both cases the sensitivity of affinity biosensor was nM level. The mechanisms of biosensor response are discussed.
Keywords :
"Biosensors","Gold","Proteins","Electrodes","Lipidomics","Chemical technology","Monitoring","Pollution","Humans","Immune system"
Publisher :
ieee
Conference_Titel :
Advanced Semiconductor Devices and Microsystems, 1998. ASDAM ´98. Second International Conference on
Print_ISBN :
0-7803-4909-1
Type :
conf
DOI :
10.1109/ASDAM.1998.730236
Filename :
730236
Link To Document :
بازگشت