DocumentCode
3675771
Title
Leakage current suppression with a novel six-switch photovoltaic grid-connected inverter
Author
Baoze Wei;Xiaoqiang Guo;Josep M. Guerrero;Mehdi Savaghebi
Author_Institution
Department of Energy Technology, Aalborg University, 9220 Aalborg East Denmark
fYear
2015
Firstpage
22
Lastpage
26
Abstract
In order to solve the problem of the leakage current in non-isolated photovoltaic (PV) systems, a novel six-switch topology and control strategy are proposed in this paper. The inductor-bypass strategy solves the common-mode voltage limitation of the conventional six-switch topology in case of unmatched inductances. And the stray capacitor voltage of the non-isolated photovoltaic system is free of high frequency ripples. Theoretical analysis and simulation are carried out to verify the proposed topology and its control strategy. Results indicate that the leakage current suppression can be achieved with the proposed solution.
Keywords
"Switches","Topology","Inductors","Leakage currents","Photovoltaic systems","Filtering"
Publisher
ieee
Conference_Titel
Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED), 2015 IEEE 10th International Symposium on
Type
conf
DOI
10.1109/DEMPED.2015.7303664
Filename
7303664
Link To Document