  • Title

    Electron density determination for plasma assisted sterilization processes

  • Author

    Christian Schulz;Jan Runkel;Ilona Rolfes

  • Author_Institution
    Institute of Microwave Systems, Ruhr-University Bochum, Bochum 44801, Germany
  • fYear
    2015
  • Firstpage
    112
  • Lastpage
    113
  • Abstract
    An effective measurement concept for the precise determination of the electron density in plasma assisted sterilization processes is presented in this paper. Here, plasmas offer a promising approach for heat or chemical sensitive materials, like surgery instruments. Therefore, the Multipole Resonance Probe (MRP) is investigated over a wide frequency range. Based on the evaluation of an unambiguous resonance behaviour, the resonance frequency can be determined from 0.5 to 6 GHz. Proven in 3D electromagnetic field simulations and measurements in an excited Argon plasma, the additional center of gravity method increases the performance and the MRP can be used for an evaluation of a wide density range. Hence, the density can be controlled effectively and used in a feedback control loop.
  • Keywords
    "Plasmas","Resonant frequency","Frequency measurement","Plasma measurements","Probes","Materials requirements planning","Density measurement"
  • Publisher
    ieee
  • Conference_Titel
    RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO), 2015 IEEE MTT-S 2015 International Microwave Workshop Series on
  • Type

    conf

  • DOI
    10.1109/IMWS-BIO.2015.7303803
  • Filename