DocumentCode
3679065
Title
Three alternative methods to determine voltage source converter losses
Author
Lassi Aarniovuori;Tatu Musikka;Antti Kosonen;Markku Niemelä;Juha Pyrhönen
Author_Institution
LAPPEENRANTA UNIVERSITY OF TECHNOLOGY, P.O. Box 20, FI-53851, Lappeenranta, Finland
fYear
2015
Firstpage
1
Lastpage
10
Abstract
The new European energy efficiency standard EN 50598-2 is in action. The standard introduces three different methods to determine the voltage source converter (VSC) losses. These methods are input-output, calorimetric, and calculation. In this paper, all these three methods are used to determine a commercial frequency converter losses and the pros and cons of all methods are highlighted and discussed.
Keywords
"Loss measurement","Frequency conversion","Semiconductor diodes","Standards","Mathematical model","Uncertainty","Temperature measurement"
Publisher
ieee
Conference_Titel
Power Electronics and Applications (EPE´15 ECCE-Europe), 2015 17th European Conference on
Type
conf
DOI
10.1109/EPE.2015.7309454
Filename