DocumentCode :
3679499
Title :
A voltage balancing control based on average power flow management for the delta-connected cascaded H-bridges converter
Author :
Hsin-Chih Chen;Ping-Heng Wu;Ching-Wei Wang;Po-Tai Cheng
Author_Institution :
Center for Advanced Power Technologies, Department of Electrical Engineering National Tsing Hua University, Hsinchu, Taiwan
fYear :
2015
Firstpage :
2104
Lastpage :
2111
Abstract :
The electric arc furnaces (EAFs) are the major disturbances in the medium-voltage level of power system for the low frequency voltage variations, which lead to incandescent lamp flickering. In order to alleviate these voltage variations, the modular multilevel cascaded converter with the topology of single-delta bridge-cell (MMCC-SDBC) is used to the medium-voltage level flicker compensator application. The voltage balancing control of MMCC-SDBC is a fundamental issue to maintain the system operation. This paper presents a voltage balancing control by zero sequence current injection based on the average power flow management. Besides, the proposed method has ability to operate at unbalanced grid voltages since both the positive and negative sequence voltages are considered. The laboratory test results show the verifications of proposed method, which are tested at a down-scaled 220V and 1kVA converter.
Keywords :
"Voltage control","Mathematical model","Furnaces","Medium voltage","Load management","Topology","Power systems"
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN :
2329-3721
Electronic_ISBN :
2329-3748
Type :
conf
DOI :
10.1109/ECCE.2015.7309957
Filename :
7309957
Link To Document :
بازگشت