DocumentCode
3679626
Title
Iron loss calculation of AC filter inductor for three-phase PWM inverter
Author
Hiroaki Matsumori;Toshihisa Shimizu;Koushi Takano;Hitoshi Ishii
Author_Institution
Tokyo Metropolitan University Tokyo, Japan
fYear
2015
Firstpage
3049
Lastpage
3056
Abstract
Two methods are proposed for evaluating the iron loss of an AC filter inductor used in a pulse-width modulation (PWM) inverter. The first method uses a loss map and calculates the iron loss without using a real PWM inverter, and the second method uses an iron loss analyzer (ILA), which can measure the iron loss during each switching period of a real PWM inverter. The authors compared the results of each method for both single-phase and three-phase PWM inverters. The calculated iron loss on the three-phase PWM inverter has a relatively large error under certain PWM pulse conditions. In order to reduce this error, a modified method is proposed, and it is shown to have a calculation error of less than 2%.
Keywords
"Iron","Loss measurement","Inverters","Pulse width modulation","Inductors","Current measurement","Switches"
Publisher
ieee
Conference_Titel
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN
2329-3721
Electronic_ISBN
2329-3748
Type
conf
DOI
10.1109/ECCE.2015.7310086
Filename
7310086
Link To Document