DocumentCode :
3680167
Title :
Analytical modeling of inter-turn short circuit for multiphase fault-tolerant PM machines with fractional-slot concentrated windings
Author :
Fan Wu;Ping Zheng;Thomas M. Jahns
Author_Institution :
Dept. of Electrical Engineering, Harbin Institute of Technology
fYear :
2015
Firstpage :
6970
Lastpage :
6977
Abstract :
Inter-turn short-circuit faults that occur inside stator coils are difficult to cope with compared to terminal short-circuit faults. A general analytical model for inter-turn short-circuit faults is developed that employs a novel T-type equivalent circuit. When this model is used to investigate the impact of inter-turn short-circuit faults in PM machines with fractional-slot concentrated windings (FSCW), the model delivers fault response predictions that agree very well with results from finite element (FE) analysis. The model is used to show that the 24-slot/14-pole FSCW PM machine is vulnerable to very high inter-turn fault currents even when the remaining turns are shorted, offsetting its advantage of low magnetic coupling between phases.
Keywords :
"Windings","Circuit faults","Magnetic circuits","Magnetic flux","Coils","Inductance","Integrated circuit modeling"
Publisher :
ieee
Conference_Titel :
Energy Conversion Congress and Exposition (ECCE), 2015 IEEE
ISSN :
2329-3721
Electronic_ISBN :
2329-3748
Type :
conf
DOI :
10.1109/ECCE.2015.7310636
Filename :
7310636
Link To Document :
بازگشت