Title :
Experience with primary reserve supplied from energy storage system
Author :
Philip C. Kjar;Rasmus Larke
Author_Institution :
Vestas Wind Syst., Technol. &
Abstract :
This paper presents practical experience obtained during the first years of operation of a 1.6MW/0.4MWh Li-ion battery energy storage system used for provision of frequency regulation and participation in the Western Denmark primary reserve market. The paper presents recorded performance during operation, identifies losses in main power conversion and auxiliary power supply, and proposes a battery charging strategy that allows compliance with the technical performance requirements from the TSO.
Keywords :
"Frequency control","Batteries","Discharges (electric)","Time-frequency analysis","Qualifications","Battery charge measurement"