DocumentCode
3682282
Title
Suppression of VCO pulling effects using even-harmonic quiet transmitting circuits
Author
Yue Wu;Tianyu Jia;Bo Xia;Xinlong Ma;Li Kang;Xiaodong Yang
Author_Institution
Vimicro Wuxi San Diego, USA
fYear
2015
Firstpage
128
Lastpage
131
Abstract
VCO TX pulling could seriously degrade transmitter performance. Unlike previous works that focus on alleviating the problem on the victim side(i.e. VCO or LO generator), we explored methods on suppressing the pulling tone generation at the transmitter side both magnetically and electrically. Magnetic differential structures and harmonic notch are employed for TX inductor/transformer and active circuits to reduce the pulling. Measurement results showed > 25dB reduction of pulling tone at +7dBm output power with <;10.5% DEVM_pk for 8-DPSK bluetooth modulation.
Keywords
"Voltage-controlled oscillators","Inductors","Harmonic analysis","Frequency modulation","Magnetic flux","Transmitters","Magnetic circuits"
Publisher
ieee
Conference_Titel
European Solid-State Circuits Conference (ESSCIRC), ESSCIRC 2015 - 41st
ISSN
1930-8833
Print_ISBN
978-1-4673-7470-5
Type
conf
DOI
10.1109/ESSCIRC.2015.7313845
Filename
7313845
Link To Document