DocumentCode :
36829
Title :
An Islanding Detection Algorithm for Inverter-Based Distributed Generation Based on Reactive Power Control
Author :
Xiaolong Chen ; Yongli Li
Author_Institution :
Dept. of Electr. Eng. & Autom., Tianjin Univ., Tianjin, China
Volume :
29
Issue :
9
fYear :
2014
fDate :
Sept. 2014
Firstpage :
4672
Lastpage :
4683
Abstract :
For the inverter-based distributed generation (DG) under constant power control, this paper analyzes the relationship between the active/reactive power mismatch and frequency deviation, respectively, during islanding and finds that the frequency variation trends caused by active and reactive power mismatches may be opposite. In order to eliminate the nondetection zone (NDZ) and detect islanding rapidly, an innovative islanding detection algorithm is presented based on a reactive power control strategy. The strategy provides the reactive power reference for the DG to guarantee the consistency of the frequency variation trends caused by both active and reactive power mismatches, thus accelerating the islanding detection speed. In addition, the introduction of the voltage variation into the proposed reactive power control strategy can regulate voltage dynamically in grid-connected mode and further shorten the islanding detection time as well. According to the antiislanding test system in the IEEE Std. 929-2000 and IEEE Std. 1547-2003, several case studies are carried out in the power systems computer-aided design/EMTDC environment. The simulation results show that the proposed algorithm has the zero NDZ property and can detect islanding rapidly. Moreover, the algorithm also performs effectively for load imbalance conditions as well as for the system with multiple DGs.
Keywords :
IEEE standards; distributed power generation; invertors; reactive power control; voltage control; EMTDC environment; IEEE Std. 1547-2003; IEEE Std. 929-2000; NDZ elimination; active power mismatch; antiislanding test; constant power control; frequency deviation; frequency variation; grid-connected mode; innovative islanding detection algorithm; inverter-based distributed generation; islanding detection speed; islanding detection time; load imbalance conditions; multiple DG; nondetection zone elimination; power systems computer-aided design; reactive power control strategy; reactive power mismatch; voltage regulation; voltage variation; Force; IEEE standards; Market research; Reactive power; Reactive power control; Resonant frequency; Voltage control; Inverter-based distributed generation; islanding detection; power factor improvement; reactive power control strategy; voltage regulation;
fLanguage :
English
Journal_Title :
Power Electronics, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8993
Type :
jour
DOI :
10.1109/TPEL.2013.2284236
Filename :
6617714
Link To Document :
بازگشت