DocumentCode
3684100
Title
Numerical analysis of the hemodynamics of an abdominal aortic aneurysm repaired using the endovascular chimney technique
Author
Hila Ben Gur;Gabor Kosa;Moshe Brand
Author_Institution
School of Mechanical Engineering, Faculty of Engineering, Tel Aviv University, 6997801, Israel
fYear
2015
Firstpage
977
Lastpage
980
Abstract
This paper presents a numerical analysis of the hemodynamics in an abdominal aorta (AA) with an aneurysm repaired by a stent graft (SG) system using the chimney technique. Computational fluid dynamics (CFD) simulations were conducted in a model of an AA repaired with a chimney stent graft (CSG) inserted into a renal artery parallel to an aortic SG and a model of a healthy AA. Comparing the simulation results of these two cases suggests that the presence of the CSG in the AA causes changes in average wall shear stress (WSS), potentially damaging recirculation zones, and additional changes in flow patterns.
Keywords
"Aneurysm","Arteries","Numerical models","Blood flow","Maintenance engineering","Mathematical model","Fluids"
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
ISSN
1094-687X
Electronic_ISBN
1558-4615
Type
conf
DOI
10.1109/EMBC.2015.7318527
Filename
7318527
Link To Document