• DocumentCode
    3684341
  • Title

    Automatic mitral annulus tracking in volumetric ultrasound using non-rigid image registration

  • Author

    Henri De Veene;Philippe B. Bertrand;Natasa Popovic;Pieter M. Vandervoort;Piet Claus;Matthieu De Beule;Brecht Heyde

  • Author_Institution
    IBiTech-bioMMeda, University of Ghent (UGent), 9000 Gent, Belgium and FEops, 9052, Belgium
  • fYear
    2015
  • Firstpage
    1985
  • Lastpage
    1988
  • Abstract
    Analysis of mitral annular dynamics plays an important role in the diagnosis and selection of optimal valve repair strategies, but remains cumbersome and time-consuming if performed manually. In this paper we propose non-rigid image registration to automatically track the annulus in 3D ultrasound images for both normal and pathological valves, and compare the performance against manual tracing. Relevant clinical properties such as annular area, circumference and excursion could be extracted reliably by the tracking algorithm. The root-mean-square error, calculated as the difference between the manually traced landmarks (18 in total) and the automatic tracking, was 1.96 ± 0.46 mm over 10 valves (5 healthy and 5 diseased) which is within the clinically acceptable error range.
  • Keywords
    "Valves","Tracking","Manuals","Ultrasonic imaging","Image registration","Three-dimensional displays","Splines (mathematics)"
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Electronic_ISBN
    1558-4615
  • Type

    conf

  • DOI
    10.1109/EMBC.2015.7318774
  • Filename
    7318774