• DocumentCode
    3685223
  • Title

    Three-dimensional reconstruction of coronary arteries and plaque morphology using CT angiography - comparison and registration using IVUS

  • Author

    Lambros S. Athanasiou;George A. Rigas;Antonios I. Sakellarios;Themis P. Exarchos;Panagiotis K. Siogkas;Lampros K. Michalis;Oberdan Parodi;Federico Vozzi;Dimitrios I. Fotiadis

  • Author_Institution
    Unit of Medical Technology and Intelligent Information Systems, Dept of Materials Science and Engineering, University of Ioannina, GR 45110
  • fYear
    2015
  • Firstpage
    5638
  • Lastpage
    5641
  • Abstract
    The aim of this study is to present a new method for three-dimensional (3D) reconstruction of coronary arteries and plaque morphology using Computed Tomography (CT) Angiography. The method is summarized in three steps. In the first step, image filters are applied to CT images and an initial estimation of the vessel borders is extracted. In the second step, the 3D centerline is extracted using the center of gravity of each rough artery border. Finally in the third step, the borders and the plaque are detected and placed onto the 3D centerline constructing a 3D surface. By using as gold standard the results of a recently presented Intravascular Ultrasound (IVUS) plaque characterization method, high correlation is observed for calcium objects detected by CT and IVUS. The correlation coefficients for objects´ volume, surface area, length and angle are r=0.51, r=0.89, r=0.96 and r=0.93, respectively.
  • Keywords
    "Computed tomography","Three-dimensional displays","Arteries","Angiography","Ultrasonic imaging","Image reconstruction","Correlation"
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Electronic_ISBN
    1558-4615
  • Type

    conf

  • DOI
    10.1109/EMBC.2015.7319671
  • Filename
    7319671