DocumentCode
3686151
Title
Pole-placement based nonlinear state-feedback control of the DC-link voltage in grid-connected voltage source power converters: A preliminary study
Author
C. Dirscherl;C. M. Hackl;K. Schechner
Author_Institution
“
fYear
2015
Firstpage
207
Lastpage
214
Abstract
We discuss pole-placement based nonlinear state-feedback control of the DC-link voltage in grid-connected voltage source power converters. For controller design we use a linearized system model, compute the feedback gains via pole placement and present an analytical expression for the gains in dependence of the actual operating point. The linearized model also allows to illustrate the non-minimum phase behavior of the DC-link dynamics for certain operation points. By online adjustment of the feedback gains, we achieve a stable closed-loop system behavior for different operation points (e.g. different reference set-points and load steps). Simulation results illustrate the control performance of a proportional state-feedback controller, a state-feedback controller with integral action and a proportional-integral state-feedback controller.
Keywords
"Voltage control","Radio frequency","Chlorine","Control systems","Reactive power","Simulation","Modulation"
Publisher
ieee
Conference_Titel
Control Applications (CCA), 2015 IEEE Conference on
Type
conf
DOI
10.1109/CCA.2015.7320634